Modules: EHC10ECК501-14,5; 10ECК402-14,5; 20EC501-29; 20EC402-29

Modules: EHC10ECК501-14,5; 10ECК402-14,5; 20EC501-29; 20EC402-29

amount
  • Voltage (V)
    13,8
№  Parameter  Module name
10EC501-14,5 10EC402-14,5 20EC501-29 20EC402-29
1 Operating voltage, V, no more than,
at temperatures:
- plus (50±2) 0С
- plus (20±5) 0С
- minus (50±2) 0С
13,8
14,5
16,0
13,8
14,5
16,0
27,5
29,0
32,0
27,5
29,0
32,0
2 Minimum voltage in the absence of current (NRC) and during storage at temperatures from minus 50 to plus 50 0С, V 4,0 4,0 8,0 8,0
3
 
Internal resistance (Rvn), Ohm, not more than,
at temperatures
- plus (20±5) 0С
- minus (50±2) 0С
0,0035
0,0035
0,016
0,003
0,003
0,008
0,007
0,007
0,021
0,006
0,006
0,015
4 Capacity (C), F, not less, at temperatures:
- plus (50±2) 0С
- plus (20±5) 0С
- minus (50±2) 0С
600
600
500
1000
1000
830
300
300
250
500
500
415
5 Delivered energy (Ер) at a temperature of plus (20 ± 5) 0С and at discharge to a load of 0.1 Ohm in the voltage range *, kJ,
no less
24 45 48 90
6 Leakage current at 25.0 V
(12,5 V for 10EC501, 10ECК402) and at temperature plus (20±5) 0С, мА, no more than
20 25 20 25
7 Voltage reduction time in the absence of current at temperatures from minus 50 to plus 50 0С, not less Voltage reduction range, V
from 13,7 to 11,0 from 11,0 to 9,0 from 9,0
to 4,0
 form 27,5 to 22,0 from 22,0 to 18,0 from 18,0 to8,0
24 hours 6 months. 3 years 24 hours 6 months. 3 years
8 Overall dimensions (length x width x height), mm, no more 350,0 x 105,0 x 194,0 350,0 x 105,0 x 249,0 350,0 x 195,0 x 191,0 350,0 x 195,0 x 253,0
9 Weight, kg, no more 9,8 14,3 19,0 26,0
10 Operating temperature range, 0С from minus 50 to plus 50
11 Storage temperature range, 0С   from minus 55 to plus 60
     Note - * Voltage range when operating in parallel with the rechargeable battery
   - from 13,0 to 6,5for modules10EC501, 10EC402;
   - from 26,0 to 13,0 for modules 20EC501, 20ЭК402.
 

Electrochemical capacitors 10EC501-14.5; 10EC402-14.5; 20EC501-29; 20EC402-29 (modules) are applied as energy sources in high-power impulse modes, for reliable starting of internal combustion engines, uninterruptible power supplies, etc.
Climatic modification of the modules is UHL, placement category is 2 in accordance with GOST 15150 for operation in the temperature ranges from minus 50 to plus 50 0С and relative air humidity up to 98% at temperatures plus (25 ± 2) 0С.