Parameter name |
Values | ||||||
Nominal capacity, Ah, no less than | 72 | ||||||
Nominal voltage, V, no less than | 3,2 | ||||||
Battery charge | |||||||
1 stage (constant current charge) | Stage 2 (charge by falling current) | ||||||
16 А | to 3,65 V | from 16 to2,2 А | to 3,65 V | ||||
Discharge to final voltage 2.5 V | |||||||
Current, А |
Capacity, A/h, no less than |
Current, А |
Capacity, A/h, no less than |
Current, А |
Capacity, A/h, no less than |
||
16 | 72 | 72 | 72 | 160 | 72 | ||
The discharge mode with a current of 16 A is considered nominal. | |||||||
Operating temperature when charging, ºС | -5 … +55 | ||||||
Operating temperature at discharge, ºС | -30 … +55 | ||||||
Cycles operating time, no less than | 300 | ||||||
Battery weight, kg, no more | 1,9 | ||||||
Overall dimensions, no more, mm | 222x136x31 |