  • Voltage (V)
    3.0
  • Capacity (Ah)
    500
Battery name
Dimensions, mm Weight, kg, max Voltage, V, no less than External circuit resistance at  voltage measurement, Ohm Discharge modes Final voltage at discharge, V, no less than
Capacity, A/h, no less than
Guaranteed storage life
1 «IMPULSE 3В-500 A/h» (38LR254/170)
Ø252,0х 170,0 12,5 3,0 3,0
Impulse
1,8
500 60

Impulse discharge mode - 0.5 s - burning // 0.5 s pause for 24 hours
day. Operating temperature range: from minus 30 to plus 400 С (capacity
batteries at minus 300 C must be at least 30% of the value,
indicated in the table).

  IMPULSE batteriesof manganese-zinc electrochemical system are intended for use as a power source for floating luminous devices of navigating equipment.