ERM P cell

ERM P cell

amount
  • Voltage (V)
    1.45
  • Capacity (Ah)
    9.0
 1 Dimensions, mm 61х 36 х 150
 2 Weight,kg, no more than 0,57
 3 voltage, V, no less at:
 4 а) Т=20÷500С 1,45
 5 б) Т= minus 40ºС 0,29
 6 External circuit resistance at voltage measurement, Ohm 1,0
 7 External circuit resistance at discharge, Ohm 10,0
 8 Capacity, A/h 9,0
 9 Final voltage, V 1,0
 10 Operating temperature range, °C from minus 40ºС to plus 50ºС
 11 Guaranteed storage life, years
5
 12 Cell voltage during storage
13 Voltage, V, no less
  1st year 2nd year
3rd year
4th year
5th year
  1,33 1,3 1,25 1,17 1,15
The cell  must be operable in the temperature range from minus 40 ° C to plus 50 ° C at a relative air humidity of 95 ± 3% at a temperature of plus 20 ° C without moisture condensation.

The cell voltage at a temperature of minus 40 ° C must be at least 20% of that indicated in the table.

The element is fire and explosion proof during operation, disposal and meets the requirements of GOST 12.2.007.12, GOST R IEC 60086-1 and GOST R IEC 60086-4.

The ERM P cell of the manganese-zinc system is designed as power supply of special-purpose equipment. ERM P is a Marine Operasting Cell in a plastic case